Bryant Furnace Error Codes: Diagnostic Guide

Bryant furnaces flash a two-digit code on a small LED visible through the burner access panel. Here is what the most common codes mean and the typical fix.

CodeMeaningTypical Fix
12Blower-on-after-power-up: 1-minute delay after power restoreNormal behaviour, wait 60 seconds
13Limit circuit lockout: high-limit tripped 3+ times in one callReset power; if recurs, replace filter and check for ductwork restrictions
14Ignition lockout: three failed ignition attemptsVerify gas supply on; clean or replace flame sensor
21Gas heating lockout: limit, ignition, or flame sense faultProfessional diagnosis required to identify the failed component
31High-pressure switch open or stuck closedInspect flue for blockage; test inducer motor and pressure tubing
33Limit circuit open (overtemperature)Replace clogged air filter immediately; verify blower motor operation

Not sure what your code means? Call us. We diagnose over the phone for free.

Common Bryant Furnace and AC Repairs

Bryant furnace won't ignite
Failed silicon-nitride igniter, low gas pressure, or pressure switch fault
Furnace short-cycling
Oversized unit, clogged filter, or thermostat sensor in direct sunlight
Bryant AC tripping breaker
Failed start capacitor, locked compressor, or shorted compressor windings
Evolution Connex thermostat offline
Loss of communication on the 4-wire ABCD bus; usually a poor crimp at the air handler
Variable-speed AC running but not cooling enough
Low refrigerant from a slow leak, or compressor not modulating up under high load
Furnace blower runs constantly
Thermostat fan setting on rather than auto, or control board G-terminal stuck

Bryant Models We Service

Evolution 987M
Up to 98.3% AFUE modulating variable-speed gas furnace. Bryant's flagship furnace.
Evolution 986T
96% AFUE two-stage variable-speed furnace. Strong balance for typical GTA homes.
Preferred 925SC
95% AFUE single-stage furnace. Reliable mid-tier replacement.
Evolution 24V
Up to 26 SEER2 variable-speed AC. Pairs with Connex thermostat for full modulation.
Preferred 187B
Up to 17 SEER2 single-stage AC. Budget-friendly replacement option.

Same-Day Bryant Repair

Most Bryant repairs are completed the same day. Our service trucks carry silicon-nitride igniters, flame sensors, pressure switches, and capacitors that fit Bryant Evolution and Preferred equipment.

Call Now

Why Choose EcoFrost for Bryant Furnace Service?

Independent Bryant Experts

We service Bryant alongside Carrier, Lennox, and every other major brand. Honest assessment, no pressure to switch.

Connex-Ready Technicians

We can wire, configure, and diagnose Bryant Evolution Connex thermostats and their 4-wire ABCD communication bus.

Same-Day Service

Most Bryant repairs completed same day with parts from our stocked service trucks.

$0 Overtime Fees

Night, weekend, or holiday: same rate always. No surprise charges on a Bryant emergency call.

Bryant Furnace and AC FAQs

How long do Bryant furnaces last?

A well-maintained Bryant furnace typically lasts 18 to 22 years. Bryant shares its parts platform with Carrier (both owned by Carrier Global), so components are widely available and serviceable across the GTA. Annual maintenance and prompt repair of minor issues drive longevity.

Is Bryant the same as Carrier?

Bryant and Carrier are sister brands under Carrier Global Corporation. They share most internal parts and the same heat exchanger designs, but Bryant typically costs 10 to 15 percent less at the dealer level. For most GTA homeowners the engineering is equivalent and Bryant is the better value.

What does a Bryant furnace error code mean?

Bryant gas furnaces flash a two-digit numeric code on a small LED on the control board. Code 13 means limit circuit lockout (almost always a clogged filter), code 14 means ignition lockout, and code 31 means a high-pressure switch fault. Call EcoFrost for a free phone diagnosis.

Does EcoFrost service Bryant furnaces and AC in Mississauga and Toronto?

Yes. EcoFrost services all Bryant Evolution and Preferred furnace and AC models across Mississauga, Toronto, Brampton, Vaughan, and the full GTA. Our service trucks stock Bryant-compatible igniters, flame sensors, capacitors, and pressure switches.

Bryant vs Carrier: which should I buy?

Engineering is nearly identical. Bryant runs 10 to 15 percent cheaper at the dealer level for the same internal hardware. Pick Carrier if your installer is a Factory Authorized Carrier dealer with deeper warranty coverage. Otherwise Bryant is the better dollar-per-feature choice.

Bryant Furnace Problem? We Fix It Today.

Same-day Bryant service across Mississauga, Toronto, Brampton, and the GTA. Independent service experts. $0 overtime fees.